Keysight N9938D FieldFox Handheld Spectrum Analyzer, 26.5 GHz
Keysight N9938D FieldFox Handheld Spectrum Analyzer, 26.5 GHz
FieldFox Handheld Spectrum Analyzer N9936D :9 kHz to 14 GHz
FieldFox Handheld Spectrum Analyzer N9937D :9 kHz to 18 GHz
FieldFox Handheld Spectrum Analyzer N9938D :9 kHz to 26.5 GHz
Go from detection to decision with the rugged, all-in-one FieldFox Handheld Analyzer.
Highlights
Capture, Analyze, and Act on Wideband Signals
FieldFox delivers all-in-one capability for spectrum monitoring, signal analysis and generation, interference
hunting, and cable and antenna testing — built for performance in both field and lab environments.
Measure signals from 9 kHz to 26.5 GHz with the Keysight N9938D FieldFox Handheld Analyzer.
▶Perform spectrum analysis, vector network analysis, cable and antenna testing, pulse generation, and
power measurements.
▶Capture elusive signals with up to 120 MHz gap-free, real-time bandwidth.
▶Stream wideband IQ data with bandwidth up to 120 MHz.
▶Make accurate spectrum analyzer measurements (±0.1 dB) without requiring instrument warm-up.
▶Use the intuitive touchscreen for simplified file management.
▶Carry one lightweight unit at 3.6 kg (8 lb) in a rugged, weatherproof design.
What's included:
▶AC / DC adapter
▶Localized power cord
▶Rechargeable Li-ion battery
▶Soft carrying case with backpack and shoulder straps
▶Quick Reference Guide
N9938D FieldFox Handheld Software
Unlock more capabilities in your FieldFox Handheld Analyzer with 25+ license-key-activated software options.
▶Carry one portable instrument for both routine maintenance and in-depth troubleshooting.
▶Configure as a VNA, spectrum analyzer, pulse generator, built-in power meter, vector voltmeter, direction finding
▶receiver, and more.
▶Order software pre-installed or upgrade your existing instrument.
Keysight Spectrum Management Software
▶Monitor the spectrum from multiple FieldFox across several frequencies or antennas.
▶Capture and display time-variant signals across multiple receivers.
▶Report frequency band and channel utilization rate.
▶Locate the source of unknown emitters and interfering signals.
Why choose FieldFox?
▶A truly software-defined analyzer, the newly introduced N9912C RF analyzer in particular, offers the
maximum flexibility and the least initial investment to meet rapidly changing market requirements
▶Ideal 5G deployment and field-testing tool with 120 MHz real-time bandwidth and over-the-air (OTA) measurements
▶Ability for 5G, satellite and radar operators to make true RF coverage measurements, up to 54 GHz and beyond,
and beamforming verification with phased array antenna support
▶Simplified field signal monitoring with wideband capture and recording of fully corrected IQ data
▶Highly efficient radar and EW systems diagnostics with spectrum analysis, full 2-port VNA, power meter, pulse
and noise figure measurements and results that correlate with high-performance bench top instruments.
▶Durable handheld analyzers that can withstand your toughest working conditions





Recently Posted
-
My BB60C Can't Pick Up Weak Signals Between 9 kHz and 20 MHz and Readings Keep Jumping — Broken Front End or Wrong Technique?
October 27, 2026My BB60C Can't Pick Up Weak Signals Between 9 kHz and 20 MHz and Readings Keep Jumping — Broken Front End or Wrong Technique?S
Read More -
BB60C IQ Recording Fails Mid-Session, Files Are Full of Gaps, or Recording Stops Early — The Problem Is the PC
October 27, 2026BB60C IQ Recording Fails Mid-Session, Files Are Full of Gaps, or Recording Stops Early — The Problem Is the PCSymptomRF/IQ recordi
Read More -
The BB60C Screen Is Full of Signals "That Shouldn't Exist" — How Do I Tell Real Signals From Instrument Artifacts?
October 27, 2026The BB60C Screen Is Full of Signals "That Shouldn't Exist" — How Do I Tell Real Signals From Instrument Artifacts?Sy
Read More -
My BB60C Reads Several dB Off Versus Another Instrument — Where Should Amplitude Errors Be Traced From?
October 27, 2026My BB60C Reads Several dB Off Versus Another Instrument — Where Should Amplitude Errors Be Traced From?SymptomOn the same signal,
Read More