Keysight N5185A MXG Analog Signal Generator N5185A-Option 506,9 kHz to 6 GHz
Keysight N5185A MXG Analog Signal Generator N5185A-Option 506,9 kHz to 6 GHz
N5185A-Option 503: 9 kHz to 3GHz
N5185A-Option 506: 9 kHz to 6 GHz
N5185A-Option 508: 9 kHz to 8.5GHz
Compact, multichannel analog signal generator with frequency coverage up to 8.5 GHz per channel
Highlights
Evolving technologies in wireless communications and aerospace and defense applications demand higher
frequency coverage using complex modulation schemes like multiple-input / multiple-output (MIMO),
beamforming, and multiplexing to maximize data throughput. The Keysight N5185A MXG analog signal
generator provides consistent and repeatable results that are ideal for multiport testing. The MXG’s custom
DAC application-specific integrated circuits (ASICs) use direct digital synthesis to deliver precise signals in
one easy-to-use box.
▶Covers frequency range from 9 kHz to 8.5 GHz with excellent phase noise and output power.
▶Supports military radio communications and MIMO tests with up to four unique outputs.
▶Reduces measurement uncertainty in power amplifier characterizations when using the embedded reflectometer.
▶Maximizes production capacity without sacrificing rack space in a 2U box.
▶Enables fast access to a dedicated team of KeysightCare technical support engineers.
Definitions and Conditions
Specifications represent warranted performance of a calibrated instrument that has been stored for a
minimum of 2 hours within the operating temperature of 0 to 55 °C, unless otherwise stated, and after a
45 minute warm-up period. The specifications include measurement uncertainty. Data represented in this
document are specifications unless otherwise noted.
Typical (typ) describes additional product performance information that is not covered by the product
warranty. It is performance beyond specifications that 80 percent of the units exhibit with a 90 percent
confidence level at room temperature (approximately 25 °C). Typical performance does not include
measurement uncertainty.
Nominal (nom) values indicate the expected mean or average performance, or an attribute whose
performance is by design, such as the 50 ohm connector. This data is not warranted and is measured at
room temperature (approximately 25 °C).
Measured (meas) describes an attribute measured during the design phase for purposes of
communicating expected performance, such as amplitude drift vs. time. This data is not warranted and is
measured at room temperature (approximately 25 °C).
Options
Accessories
11900B: Adapter 2.4 mm female to 2.4 mm female
11900C: Adapter 2.4 mm male to 2.4 mm female
11901B: Adapter 2.4 mm female to APC-3.5 female
11901C: Adapter 2.4 mm male to APC-3.5 female
11904C: Adapter 2.4 mm male to 2.92 mm female
83059B: Coaxial Adapter, 3.5mm Female-Female
83059C: Coaxial Adapter, 3.5mm Male-Female
Y1311A: Additional removable M.2 drive
Y1310A: Additional removable SD card
Y1313A: Micro HDMI to Micro HDMI cable







Recently Posted
-
Key Performance Benefits of SM200B 160 MHz Instantaneous Bandwidth
September 9, 2026Key Performance Benefits of SM200B 160 MHz Instantaneous BandwidthTitle:Why 160 MHz Instantaneous Bandwidth Matters for SM200B Mon
Read More -
Product Overview — What Is SM200B Real-Time Spectrum Analyzer and Monitoring Receiver
September 9, 2026Product Overview — What Is SM200B Real-Time Spectrum Analyzer and Monitoring ReceiverTitle:SM200B Real-Time Spectrum Analyzer &
Read More -
Dongguan Chenyi Electronics: Your Professional RF Test and Measurement Instrument Supplier in Donggu
September 3, 20261. A Supplier That Understands What You Are Actually MeasuringBuying test instruments from a supplier that only moves boxes is a d
Read More -
RF Test Instrument Calibration Intervals and Methods: Best Practices for Ensuring Measurement Accura
September 3, 20261. The 3 dB Error That Nearly Cost a CertificationA compliance engineer preparing a product for regulatory certification noticed t
Read More