Keysight E4982A LCR Meter, 1 MHz To 300 MHz or 500 MHz or 1 GHz or 3 GHz
Keysight E4982A LCR Meter, 1 MHz To 300 MHz or 500 MHz or 1 GHz or 3 GHz
E4982A-050:1 MHz to 500 MHz
E4982A-100:1 MHz to 1 GHz
E4982A-300:1 MHz to 3 GHz
E4982A-030:1 MHz to 300 MHz
Key features
Unparalleled measurement speed and repeatability
▶0.9 msec (measurement time mode 1)
▶2.1 msec (measurement time mode 2)
▶3.7 msec (measurement time mode 3)
▶Low variation for repeatability
Excellent accuracy and wide impedance range
▶11 parameters: |Z|, |Y|, L, C, R, X, G, B, D, Q, ø
▶Measurement range from 0.14 Ω to 4.8 kΩ (within 10% accuracy)
▶0.8% basic accuracy
▶Sophisticated calibration/compensation method with calibration wizard function
System Integration Capability with 4287A compatibility
▶SCPI commands
▶GPIB, LAN, USB, Handler interface
▶Cable extension and small test head (the same size as the 4287A)
▶Multi-function comparator
▶Contact check using DCR measurement function
New functions which are not in 4287A
▶List measurement up to 201 points/table, table and plot format
▶User defined function keys/parameters
▶Undo recall/preset
▶Context sensitive embedded help
The E4982A LCR meter provides the best performance for passive component manufacturing such as SMD inductors and EMI filters where impedance testing at high frequencies (1 MHz to 300 MHz / 500 MHz / 1 GHz / 3 GHz) is required.
Highlights
New Standard for High-Speed Component Tests
Keysight E4982A LCR meter provides the best performance for the passive component manufacturing such as SMD inductors and EMI filters, where impedance testing at high frequencies is required. Not only for the manufacturing, E4982A can also be utilized for R&D, quality assurance with the powerful functions such as list measurements. By offering the unparalleled measurement speed and repeatability with excellent accuracy and impedance range, E4982A is the new standard for high speed component tests.
Frequency
▶Four frequency options: 1 MHz to 300 MHz / 500 MHz / 1 GHz / 3 GHz, upgradeable
Measurement Time
▶High-speed measurement: 0.9 ms (Mode 1), 2.1 ms (Mode 2), 3.7 ms (Mode 3)
Basic Accuracy And Impedance Range
▶0.8% basic accuracy with unparalleled measurement repeatability
▶Wide impedance measurements range from 140 mΩ to 4.8 kΩ
More Features
▶Compatible SCPI commands and Handler interface with the 4287A LCR meter
▶Small test head (the same size as 4287A)
▶List measurement
▶Versatile PC connectivity (GPIB, LAN, and USB)





Recently Posted
-
My BB60C Can't Pick Up Weak Signals Between 9 kHz and 20 MHz and Readings Keep Jumping — Broken Front End or Wrong Technique?
October 27, 2026My BB60C Can't Pick Up Weak Signals Between 9 kHz and 20 MHz and Readings Keep Jumping — Broken Front End or Wrong Technique?S
Read More -
BB60C IQ Recording Fails Mid-Session, Files Are Full of Gaps, or Recording Stops Early — The Problem Is the PC
October 27, 2026BB60C IQ Recording Fails Mid-Session, Files Are Full of Gaps, or Recording Stops Early — The Problem Is the PCSymptomRF/IQ recordi
Read More -
The BB60C Screen Is Full of Signals "That Shouldn't Exist" — How Do I Tell Real Signals From Instrument Artifacts?
October 27, 2026The BB60C Screen Is Full of Signals "That Shouldn't Exist" — How Do I Tell Real Signals From Instrument Artifacts?Sy
Read More -
My BB60C Reads Several dB Off Versus Another Instrument — Where Should Amplitude Errors Be Traced From?
October 27, 2026My BB60C Reads Several dB Off Versus Another Instrument — Where Should Amplitude Errors Be Traced From?SymptomOn the same signal,
Read More