Keysight 3458A Digital Multimeter, 8.5 digit multimeter
Keysight 3458A Digital Multimeter, 8.5 digit multimeter
Highlights
Reliably Accurate Measurements Every Time
The Keysight 3458A, 8.5 digit multimeter, has a 30-year industrial-benchmark legacy for remarkable DC accuracy and stability. The redesigned 3458A multimeter also has standard lab 8.5-digit precision with leading-edge DCV linearity accuracy, the lowest internal noise, and it is RoHS compliant.
The 3458A is recognized the world over as the standard in high-performance digital multimeters,
provides both speed and accuracy in the R&D lab, on the production test floor, and in the calibration
lab. The Keysight 3458A is simply the fastest, most flexible, and most accurate multimeter ever offered
by Keysight Technologies. In your system or on the bench, the Keysight 3458A saves you time and money with unprecedented test system throughput and accuracy.
▶Measure with confidence with up to 8 ppm 1-year direct current voltage (DCV) accuracy (4 ppm with option)
▶Maximize productivity with fast measurement speeds up to 100,000 readings/s
▶Prolonged data logging with up to 148,000 reading memory (now comes as standard)
▶Self-adjusting and self-verifying auto-calibration capability
▶Code compatible with previous version; RoHS compliant
High Speed and High Accuracy for Your Most Demanding Applications
With seven-function measurement flexibility and a convenient front panel, the 3458A enables:
▶faster test system startup, faster test throughput, and longer system up-time
▶usage as a calibration lab standard through its extraordinary linearity, low internal noise, and very
high stability
▶high-resolution digitizing with 16- to 24-bit resolution, up to 12 MHz bandwidth path, high sampling rate, and very low <100 ps jitter performance
Digital Multimeter, 8 ½ Digit
▶Measure with confidence with up to 8 ppm 1-year direct current voltage (DCV) accuracy (4ppm with option)
▶Maximize productivity with fast measurement speeds up to 100,000 readings/s
▶Prolonged data logging with up to 148,000 reading memory (now comes as standard)
▶Self-adjusting and self-verifying auto-calibration capability
▶Code compatible with previous version
▶RoHS compliant







Recently Posted
-
My BB60C Can't Pick Up Weak Signals Between 9 kHz and 20 MHz and Readings Keep Jumping — Broken Front End or Wrong Technique?
October 27, 2026My BB60C Can't Pick Up Weak Signals Between 9 kHz and 20 MHz and Readings Keep Jumping — Broken Front End or Wrong Technique?S
Read More -
BB60C IQ Recording Fails Mid-Session, Files Are Full of Gaps, or Recording Stops Early — The Problem Is the PC
October 27, 2026BB60C IQ Recording Fails Mid-Session, Files Are Full of Gaps, or Recording Stops Early — The Problem Is the PCSymptomRF/IQ recordi
Read More -
The BB60C Screen Is Full of Signals "That Shouldn't Exist" — How Do I Tell Real Signals From Instrument Artifacts?
October 27, 2026The BB60C Screen Is Full of Signals "That Shouldn't Exist" — How Do I Tell Real Signals From Instrument Artifacts?Sy
Read More -
My BB60C Reads Several dB Off Versus Another Instrument — Where Should Amplitude Errors Be Traced From?
October 27, 2026My BB60C Reads Several dB Off Versus Another Instrument — Where Should Amplitude Errors Be Traced From?SymptomOn the same signal,
Read More