rohde schwarz RTP064B Oscilloscope RTP064B: 6 GHz , 4 Channels
rohde schwarz RTP064B Oscilloscope RTP064B: 6 GHz , 4 Channels
Oscilloscope RTP044B: 4 GHz , 4 Channels
Oscilloscope RTP064B: 6 GHz , 4 Channels
Oscilloscope RTP084B: 8 GHz , 4 Channels
Oscilloscope RTP0134B:13/8 GHz , 2/4 Channels
Oscilloscope RTP0164B:16/8 GHz , 2/4 Channels
Key facts
▶Bandwidth: 4 GHz to 16 GHz
▶Max. sample rate: 40 Gsample/s
▶Max. memory depth: 3 Gpoints per channel
▶Up to 16 bit resolution
▶All trigger events at full bandwidth
Signal integrity in real time
The R&S®RTP high-performance oscilloscope combines high-class signal integrity with a fast acquisition rate. Customized frontend ASIC and real-time processing hardware enable highly accurate measurements with unprecedented speed in a compact form factor.
▶750,000 waveforms/s to find faults fast
▶High-precision digital trigger with no bandwidth limitations
▶Real-time deembedding for triggering and fast acquisition
▶Compact design and silent operation to best fit any lab
▶Precise measurements with flat frequency response of +/- 0.25 dB
Features & benefits
Real-time signal integrity
Fastest high accuracy measurements
Rohde & Schwarz has the in-house expertise to design the best analog integrated circuits. Powerfulprocessing components directly downstream from the A/D converters enable real-time correction oftransmission paths from the DUT, retaining the maximum acquisition rate of 750,000 waveforms/s.
▶Flat frequency response and high spurious-free dynamic range for precise measurements
▶Real-time deembedding for fast acquisition and precise triggering
▶Real-time math for differential signals
▶Hardware-accelerated histogram and mask test
▶Increase real-time resolution with 16-bit HD mode
Multi-instrument capability
Time-correlated measurements on integrated devices
The R&SeRTP oscilloscope combines several test instrument capabilities for time-correlated analysis ofmultiple signal types in a single box.
▶High bandwidth analog channels for measuring high-speed signals and wideband RF transmitters
▶Fast and responsive FFT for analysis in the frequency domain
▶General purpose 16 ch, 400 MHz MSO for logic analysis or protocol based testing of low-speed serialbuses
▶Select from the broad portfolio of serial protocol options
▶Multiple 18-bit high-precision voltage and current channels (4 + 4)
▶2 ch 100 MHz arbitrary waveform generator
▶16 GHz differential pulse source
Compact and configurable
Future-proof 4 to 16 GHz platform for any lab
The R&SeRTP platform is designed for minimal bench space and quiet operation. ultiple option slotsand upgrade paths for bandwidth and memory make for a safe investment and a future-proof platform
▶Most compact and silent high-performance oscilloscope for your lab
▶Expand as your requirements grow: 4 hardware option slots, software option, bandwidth andmemory upgrade
▶Quickly operate instrument via touchscreen and established Rohde & Schwarz graphical userinterface




Recently Posted
-
My BB60C Can't Pick Up Weak Signals Between 9 kHz and 20 MHz and Readings Keep Jumping — Broken Front End or Wrong Technique?
October 27, 2026My BB60C Can't Pick Up Weak Signals Between 9 kHz and 20 MHz and Readings Keep Jumping — Broken Front End or Wrong Technique?S
Read More -
BB60C IQ Recording Fails Mid-Session, Files Are Full of Gaps, or Recording Stops Early — The Problem Is the PC
October 27, 2026BB60C IQ Recording Fails Mid-Session, Files Are Full of Gaps, or Recording Stops Early — The Problem Is the PCSymptomRF/IQ recordi
Read More -
The BB60C Screen Is Full of Signals "That Shouldn't Exist" — How Do I Tell Real Signals From Instrument Artifacts?
October 27, 2026The BB60C Screen Is Full of Signals "That Shouldn't Exist" — How Do I Tell Real Signals From Instrument Artifacts?Sy
Read More -
My BB60C Reads Several dB Off Versus Another Instrument — Where Should Amplitude Errors Be Traced From?
October 27, 2026My BB60C Reads Several dB Off Versus Another Instrument — Where Should Amplitude Errors Be Traced From?SymptomOn the same signal,
Read More