rohde schwarz ZNA67 Vector network analyzers,10 MHz to 67 GHz
rohde schwarz ZNA67 Vector network analyzers,10 MHz to 67 GHz
Key Features:
▶ Frequency Range: 10 MHz ~ 67 GHz
▶ Full Touchscreen
▶ Intuitive and Easy to Use
▶ DUT-Centric Test Wizard
▶ Built-in 4 Signal Source Modes
▶ Configurable Second Local Oscillator for Enhanced Stability
Key facts
10 MHz to 26.5/43.5/50/67 GHz (R&S®ZNA26/43/50/67) 10 MHz to 110 GHz (R&S®ZNA67EXT)
Two or four port models available
Excellent RF-performance
Up to four integrated sources
Unique and intuitive touch-only operation
Masters the most challenging measurement tasks
The R&S®ZNA vector network analyzers are the high-end series in the Rohde & Schwarz VNA portfolio: excellent RF-performance is combined with a wide range of software features and a unique hardware concept. The touch-only operation together with the DUT-centric approach makes the R&S®ZNA a powerful, universal and compact measurement system for characterizing passive and active devices.
Available models
Models:R&S®ZNA26 Order number 1332.4500.22
Ports: 2 ports
Frequency:10 MHz to 26.5 GHz
Connectors:3.5 mm(m)
Models:R&S®ZNA26 Order number 1332.4500.24
Ports: 4 ports
Frequency:10 MHz to 26.5 GHz
Connectors:3.5 mm(m)
Models:R&S®ZNA43 Order number 1332.4500.42
Ports: 2 ports
Frequency:10 MHz to 43.5 GHz
Connectors:2.92 mm(m)
Models:R&S®ZNA43 Order number 1332.4500.43
Ports: 2 ports
Frequency:10 MHz to 43.5 GHz
Connectors:2.4 mm(m)
Models:R&S®ZNA43 Order number 1332.4500.44
Ports: 4 ports
Frequency:10 MHz to 43.5 GHz
Connectors:2.92 mm(m)
Models:R&S®ZNA43 Order number 1332.4500.45
Ports: 4 ports
Frequency:10 MHz to 43.5 GHz
Connectors:2.4 mm(m)
Models:R&S®ZNA50 Order number 1332.4500.52
Ports: 2 ports
Frequency:10 MHz to 50 GHz
Connectors:2.4 mm(m)





Recently Posted
-
My BB60C Can't Pick Up Weak Signals Between 9 kHz and 20 MHz and Readings Keep Jumping — Broken Front End or Wrong Technique?
October 27, 2026My BB60C Can't Pick Up Weak Signals Between 9 kHz and 20 MHz and Readings Keep Jumping — Broken Front End or Wrong Technique?S
Read More -
BB60C IQ Recording Fails Mid-Session, Files Are Full of Gaps, or Recording Stops Early — The Problem Is the PC
October 27, 2026BB60C IQ Recording Fails Mid-Session, Files Are Full of Gaps, or Recording Stops Early — The Problem Is the PCSymptomRF/IQ recordi
Read More -
The BB60C Screen Is Full of Signals "That Shouldn't Exist" — How Do I Tell Real Signals From Instrument Artifacts?
October 27, 2026The BB60C Screen Is Full of Signals "That Shouldn't Exist" — How Do I Tell Real Signals From Instrument Artifacts?Sy
Read More -
My BB60C Reads Several dB Off Versus Another Instrument — Where Should Amplitude Errors Be Traced From?
October 27, 2026My BB60C Reads Several dB Off Versus Another Instrument — Where Should Amplitude Errors Be Traced From?SymptomOn the same signal,
Read More