rohde schwarz FPL1026 Spectrum analyzer ,5 kHz to 26.5 GHz
rohde schwarz FPL1026 Spectrum analyzer ,5 kHz to 26.5 GHz
Key facts
Frequency range 5 kHz to 26.5 GHz
SSB phase noise: typ. –108 dBc (1 Hz) at 10 kHz
DANL with preamplifier: typ. –163 dBm from 10 MHz to 2 GHz
Lightweight with small footprint
40 MHz analysis bandwidth (option)
Spectrum and vector network analyzer promotion
Key Features
▶ Frequency Range: 5 kHz ~ 26.5 GHz
▶ SSB Phase Noise: –108 dBc / Hz (10 kHz Offset)
▶ Display Average Noise Level: -166 dBm@2 GHz (Preamplifier ON, Typical Value)
▶ DC Power Supply (12 V / 24 V)
▶ Depth Only 23.5 cm, Space-Saving Design
▶ Built-in Tracking Source (Opt.)
Brief description
In RF labs, FPL instruments are indispensable oscilloscopes or multimeters. A single instrument can perform many measurement tasks. FPL analyzers can be used for spectrum analysis, highly accurate power measurements for power sensors and analysis of analog and digitally modulated signals.
Available models
Models :R&S®FPL1003 Order number 1304.0004.03
Frequency range :5 kHz - 3 GHz
Phase noise :<–108 dBc (1 Hz) (f = 1 GHz, 10 kHz offset)
DANL @ 1 GHz:<–163 dBm/Hz
Max. analysis bandwidth:40 MHz (FPL1-B40)
Instrument type:Signal and spectrum analyzer
Models :R&S®FPL1007 Order number 1304.0004.07
Frequency range :5 kHz - 7.5 GHz
Phase noise :<–108 dBc (1 Hz) (f = 1 GHz, 10 kHz offset)
DANL @ 1 GHz:<–163 dBm/Hz
Max. analysis bandwidth:40 MHz (FPL1-B40)
Instrument type:Signal and spectrum analyzer
Models :R&S®FPL1014 Order number 1304.0004.14
Frequency range :5 kHz - 14 GHz
Phase noise :<-108 dBc (1 Hz)(f=1 Ghz, 10 kHz offset)
DANL @ 1 GHz:<-160 dBm/Hz Pre-amp on
Max. analysis bandwidth:40 MHz (FPL1-B40, and FPL1-B11)
Instrument type:Signal and spectrum analyzer
Models :R&S®FPL1026 Order number 1304.0004.26
Frequency range :5 kHz - 26.5 GHz
Phase noise :<-108 dBc (1 Hz) (f=1 GHz, 10 kHz offset)
DANL @ 1 GHz: <-160 dBm/Hz Pre-amp on
Max. analysis bandwidth: 40 MHz (FPL1-B40, and FPL1-B11)
Instrument type:Signal and spectrum analyzer






Recently Posted
-
My BB60C Can't Pick Up Weak Signals Between 9 kHz and 20 MHz and Readings Keep Jumping — Broken Front End or Wrong Technique?
October 27, 2026My BB60C Can't Pick Up Weak Signals Between 9 kHz and 20 MHz and Readings Keep Jumping — Broken Front End or Wrong Technique?S
Read More -
BB60C IQ Recording Fails Mid-Session, Files Are Full of Gaps, or Recording Stops Early — The Problem Is the PC
October 27, 2026BB60C IQ Recording Fails Mid-Session, Files Are Full of Gaps, or Recording Stops Early — The Problem Is the PCSymptomRF/IQ recordi
Read More -
The BB60C Screen Is Full of Signals "That Shouldn't Exist" — How Do I Tell Real Signals From Instrument Artifacts?
October 27, 2026The BB60C Screen Is Full of Signals "That Shouldn't Exist" — How Do I Tell Real Signals From Instrument Artifacts?Sy
Read More -
My BB60C Reads Several dB Off Versus Another Instrument — Where Should Amplitude Errors Be Traced From?
October 27, 2026My BB60C Reads Several dB Off Versus Another Instrument — Where Should Amplitude Errors Be Traced From?SymptomOn the same signal,
Read More